CI-PC81 High Content Oxygen Analyzer
CI-PC81 high content oxygen analyzer takes 3D ion flow oxygen sensor as measuring unit and microcontroller as core. It adopts double sensor technology and digital processing technology, which makes the analyzer intelligent, high precision, good stability, long calibration period and long service life.
1. With microprocessor as the core and the 3D ion flow oxygen sensor as measurement unit,it has the
characteristics of intelligence,stability, high precision and long calibration cycle.
2. Double pool thick film co-firing technology is adopted,and the service life of the sensor is long.
3. Automatic calibration function:The analyzer has automatic calibration function.After connecting the standard
gas according to the method specified by the manufacturer,it can complete the calibration of the analyzer
automatically.
4. Pressure detection function:test the relative pressure inside the gas path,judge whether the gas path is
blocked,when the sample pressure exceeds the set range,it will give an alarm;
5. Pressure compensation function:the analyzer has advanced pressure compensation function,which can
eliminate the influence of pressure on the accuracy of oxygen concentration measurement;
6. Menu lock switch:prevent misoperation and change of analyzer parameters from affecting its normal
operation;
7. Alarm function:When the oxygen concentration deviates from the alarm value,the alarm value can be set
arbitrarily in the full range.
8. Communication function:RS232(standard) and RS485(optional) two-way communication can be used to
communicate directly with computers or other digital communication equipment.
Measure Range: 10.00%~99.999% O2
Sensor : 3D Ion flow oxygen sensor
Accuracy: ±1%FS
Repeatability: ±0.5%FS
Stability: ±0.5%/7d
Response time: T9o<2Os
Circuit structure: applied to non hazardous situations.
Data storage: SD Card (Standard)/U Disk (Optional)
Power supply: 85~264VAC,50/60Hz
Analyzer power consumption: <35VA
Communication: RS485(standard)/RS232 (optional)
Switch output: 6 sets
Relay contact point capacity: 24V DC.0.2A
Analog output: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-1OV/1 -5V (You can set the mode freely).
The load: less than 500 Q
External input: Five groups Control signal 9-28VDC
Environment temperature: -10~45°C Environment Humidity:<90%RH
Sample gas pressure: atmospheric conditions±10% (Gas outlet should be atmospheric conditions)
Instrument size: LxWxH=483mmx300mmx177mm
Order knowledge
Measure range
Tested gas pressure
Gas composition and impurity