Secured Trading Service

P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester

  • Audited Supplier
  • 7 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Advanced Ion Current Sensor: Adopts single chip technology with fast response and high sensitivity for accurate measurement.
  • Wide Measurement Range: Supports 100ppm to 21% for O2 and N2, with customizable ranges for other gases like NOx and CO2.
  • Automatic Temperature Compensation: High precision system eliminates environmental temperature impact on measurement accuracy.
  • Customizable Design: Offers flexible customization for range, analog output, and gas components based on user requirements.
  • Dual-Line Working Mode: Unique double-line working change mode extends sensor life and ensures continuous operation.
  • Comprehensive Certification: Product holds CE certification and factory operates under ISO9001 quality management system.
  • Flexible Analog Output: Supports multiple signal modes including 4-20mA, 0-20mA, and various voltage ranges.
  • Global After-Sales Support: Provides online instructions, overseas engineers, and worldwide agents for installation and maintenance.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester

P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester pictures & photos
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester pictures & photos
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester pictures & photos
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester pictures & photos
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester pictures & photos
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester pictures & photos
P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
    P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
    P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
    P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
    P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
    P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
  • P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
    P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester

Find Similar Products

Product Description

P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester
Product Description

 

P860 Nitrogen Oxygen Analyzer Portable Oxygen Purity Analyzer 100ppm~21%

P860 series analyzer is the online intelligent measurement instrument, which adopting advanced ion current oxygen sensor with single chip technology. N2%=100%-O2%. It has been widely used in the fields of nitrogen separation from air, fertilizer, petrochemicals and biological fermentation.

Features

  • New pattern long-life conversion ion current tester with fast response and high sensitivity
  • N2 or O2 concentration display
  • Checking the sensor working state automatically and unique double-line working change mode extending the sensor's life
  • Setting alarm value freely
  • High precision, automatic temperature compensation, eliminating the impact of environmental temperature
Our Advantages

P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ TesterTechnical Parameters
Model: CI-PC21
Measuring principle: NDIR non-optical infrared analyzer
Measuring component: any one or two components can be measured NOx,SO2,CO,CO2,CH4,H2S. O2 Can be added to each component

Range based
Required design
Minimum Range Maximum range
NOx 0 to 1000 ppm 0-20%
SO2 ppm 0-500 0-100%
CO 0 to 20 ppm 0-100%
CO2 0 to 10 ppm 0-100%
CH4 0 to 200 ppm 0-100%
H2S 0 to WOO ppm 0-30%
 
Accuracy ± 2%FS
Repeatability ±1%FS
Zero Drift ±1%FS/7d
Range Drift ±1%FS/7d
Linear Error Limit ±1%FS
Response Time T90<=60 s (sample flow 0.5 L/min)
Analog Signal 4~20 mA/0~20mA/0~1 V/0-5V/0-10V/1-5V, can set analog output mode freely
Maximum Load provided according to user requirements, not affected by load within 500Ω maximum load
Ambient Temperature -10~45°C
Ambient Humidity less than 80% RH
Supply voltage 85-264 VAC 50/60HZ
Size 19-inch profile chassis L * W * H=483 mm * 300mm *177mm
Gas flow measured 500~1000 ml/min, 500 ml/min best
Dust particles not exceeding I um, not exceeding 200 μg/Nm3
Pressure 10%± atmospheric pressure (air outlet should be atmospheric pressure)
Moisture no more than 5 P saturated (no condensation)

P860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ TesterP860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ TesterP860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ TesterP860 Series N2/O2 Analyzer Oxygen and Nitrogen Gas Purity Analyzer/ Tester

1.Q:Where is your factory located? How can I visit there?
A:We are the professional gas equipments, founded in 2008. Our factory is located in Beijing China . Welcome to visit us!
2.Q:What's your delivery time?
A:As usual 40 days,if urgently order,pls contact our sales in advance.
3.Q:How does your factory do regarding quality control?
A:Quality is everything. we always attach great importance to quality controlling from the very beginning to the very end. Our
factory has gained ISO9001 and CE certificate.
4.Q:What's payment term?
A:T/T, L/C etc.Also we could accept USD, RMB, Euro and other currency.
5.Q:How about your after-sales service?
(1) Provide customers with installation and commissioning online instructions.
(2) Well-trained engineers available to overseas service.
(3) Worldwide agents and after service available.

 

 

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASR246111". Items marked "verified" are certified.

Watch Video
Watch Video
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD
BeiJing Cape Golden Gas System Company LTD

About Our Factory & Business Background

Address
N525 No.86 Wanxing Road Changyang, Fangshan District, Beijing, China
verified Terms of Payment
LC, T/T, D/P, PayPal
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: within 15 workdays, one month
Off Season Lead Time: within 15 workdays, one month
verified Nearest Port
Tianjin Port, Qingdao Port, Shanghai Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
20

Our Production Capability & Technical Expertise

Main Products
Psa Oxygen Generator, Psa Nitrogen Generator, Air Compressor, Refrigeration Dryer, Storage Tank, Vpsa Oxygen Generator, Filter&amp; Element, Oxygen Analyzer, Nitrogen Analyzer, Booster
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
3 people

Our Industry Experience & Global Business Record

verified Export Year
5 Years
verified Main Markets
North America, South America, Europe, Southeast Asia/ Mideast, Africa, East Asia(Japan/ South Korea), Australia
verified Number of Foreign Trading Staff
6
verified Overseas Agent/Branch
No
verified New Products Launched in Last year
No

FAQ

Where is your factory located and can I visit?
Our factory is located in Beijing, China. We are a professional gas equipment manufacturer founded in 2008 and welcome visitors.
What is the delivery time for orders?
The usual delivery time is 40 days. For urgent orders, please contact our sales team in advance.
How do you ensure product quality?
Quality is our priority. We control quality from start to finish and hold ISO9001 and CE certificates.
What are the payment terms?
We accept T/T, L/C, D/P, and PayPal. Currencies accepted include USD, RMB, Euro, and others.
What after-sales services do you provide?
We provide online installation instructions, well-trained engineers for overseas service, and worldwide agents.
Is customization available for this analyzer?
Yes, we offer full customization, minor customization, and flexible options based on samples or designs.
What is the minimum order quantity?
The minimum order quantity is 1 unit.
What are the lead times during peak and off-peak seasons?
Both peak and off-peak season lead times are within 15 workdays to one month.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now