Ci-PC56 Thermal Conductive Hydrogen Analyzer for Hydrogen Concentration Online Measurement
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| After-sales Service: | Overseas Service Available |
| Warranty: | 36months |
Diamond Member Since 2020
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
High Repeat Buyers Choice
Experienced Team
Management Certification
The supplier has import and export rights
More than 50% of buyers repeatedly choose the supplier
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
The supplier has quality management system certification, including:
ISO9001:2015 certificate
Medical Device Quality Management System Certification
ISO9001:2015 certificate
Medical Device Quality Management System Certification
Sign In to see all verified strength labels (17)
Find Similar Products
Basic Info.
- Place of Origin
- Shanghai China (Mainland)
- Accuracy
- ≤±5% F.S(10~100ppm); ≤±2%
- Measure Range
- 0~99.9%/99.99%/99.999% H2
- Sensor Life
- 20000 Hours
- Transport Package
- as Per Customer Request
- Specification
- SGS
- Trademark
- ChangAi
- Origin
- Beijing, China.
- HS Code
- 9027100090
- Production Capacity
- 200 Units Per Month
Product Description
CI-PC56 Thermal Conductivity Type Hydrogen Analyzer

Main Features

Working Parameters :
| Component gas | Background gas | Min Range | Max Range |
H2 |
Air | 0~1% | 0~99.999% |
| N2 | 0~1% | 0~99.999% | |
| O2 | 0~1% | 0~99.999% | |
| Ar | 0~1% | 0~99.999% | |
| CO | 0~1% | 0~99.999% | |
Ar |
Air | 0~1% | 0~99.99% |
| N2 | 0~1% | 0~99.99% | |
| O2 | 0~1% | 0~99.99% | |
| CO2 | 0~1% | 0~99.99% | |
| He | N2 | 0~1% | 0~99.99% |
| D2 | N2 | 0~1% | 0~99.99% |
| The component and measure range are costumed be users. | |||

Main Features
- Is based on microprocessor and it has characteristics as intelligence, good stability, high reliability.
- It adopts heat-conduction sensor as the measuring unit and it has high accuracy, long calibration cycle.
- 128×64 LCD shows H2 concentration, menu, set value and analyzer work state, etc. It has visualized show and handy operation. Window surface is covered by a toughened glass so it has a good protection effect.
- Auto range, it will automatically switch analog output range to improve accuracy of analog output according to the range where gas concentration is
- Interference gas compensation function, eliminate the influence of test by interference gas to improve accuracy of test
- Menu lock, prevent the influence for analyzer from mis operation.
- It adopts touch key of the latest technology to extend the service life of buttons.
- RS485/RS232 (optional) 2-way communication function, can communicate directly with computer or other digital communication equipment.
- Isolated analog signal output, analog signal mode can be set through analyzer as 4-20mA, 0-20mA, 0-1V, 0-5V, 0-10V freely
- It has simple structure and it is convenience to operate and maintain.
Technical Specifications
Performance Specifications:
| Sensor | Thermal conductivity sensor |
| Accuracy | ±2% |
| Repeatability | ±1% |
| Stability | ±1%/7d |
| Response time | T90<60s (After preheating enough) |
| Calibration period | Once a year (recommend) |
| Sensor life | More than 2 years(normal use) |
| Instrument life | More than 5 years(normal use) |

Working Parameters :
CI-PC56 thermal conductivity gas analyzer is based on microprocessor and adopts heat-conduction sensor as the measuring unit. It has characteristics as high accuracy, good stability, complete functions, and long service life and so on. It applies to the accurate measurement of H2, Ar content in binary mixed gas.
Range
Range
| Operation mode |
Online |
| Sample mode | Plug-in measurement(optional) or ventilation |
| Power supply | AC85~264V,50/60Hz |
| Consumption | Less than 20VA |
| Working temperature |
Operating: 5~+45ºC Storing: -5~+50ºC |
| Working humidity | <90%RH |
| Intake pressure | atmospheric conditions±10% (Gas outlet should be atmospheric conditions) |
| Intake flow | 200~400ml/min |
Input and Output Parameters:
| Communication | RS485(standard) / RS232(optional) |
| Switch signal | Quantity: 5 group Relay contact point capacity: 24VDC, 0.2A |
Analog signal |
Quantity: two group output mode: 4-20mA/ 0-20mA/ 0-1V/ 0-5V/ 0-10V/ 1-5V, can be set freely load: less than 500Ω |
External control |
Quantity: 1 group Control signal: 9~28VDC Function: only used to control the pump(optional) |
Interference compensation |
Quantity: two group mode: DC 4-20mA (default interference gas is CO, CO2. If there is other interference gas, please explain when ordering.) |
CI-PC56 Front/Back Panel Size (unit: mm)
Applications
- Air Separation;
- Chemical Application;
- Wood Gasification;
- Gas Detection in Production and Manufacture;
- Protection Gas Detection;
- Gas Detection in Blast Furnace;
- Gas Detection for Acidic Converter;
- Generator Detection in Hydrogen Refrigeration Generator



How to order
1. Measure range
2. Tested gas pressure
3. Gas composition and impurity
Send your message to this supplier
People who viewed this also viewed
Find Similar Products By Category
- Supplier Homepage
- Products
- Gas Instrument Analyzer
- Ci-PC56 Thermal Conductive Hydrogen Analyzer for Hydrogen Concentration Online Measurement
Related Categories
Hot Searches
More