Customization: | Available |
---|---|
Place of Origin: | Shanghai China (Mainland) |
Sensor Life: | 20000 Hours |
Still deciding? Get samples of US$ 9000/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
The factory price Online Infrared Environment Monitoring oxygen GAS analyzer for O2, N2,So2, Co, CO2,H2
The selective absorption of infrared by gas molecules is the basis of the design of infrared gas analyzer.S02,NOx,C02,CO,CH4 and other polar molecules have permanent electric torch, so it has vibration, rotation and other structures. According to quantum mechanics, the energy level of splitting can be coupled with the incident characteristic long infrared radiation to produce absorption, and different polar molecules are absorbed by different spectral bands.
Range based Required design |
Minimum Range | Maximum range |
NOx | 0 to 1000 ppm | 0-20% |
SO2 | ppm 0-500 | 0-100% |
CO | 0 to 20 ppm | 0 ~100% |
CO2 | 0 to 10 ppm | 0 ~100% |
CH4 | 0 to 200 ppm | 0-100% |
H2S | 0 to WOOppm | 0-30% |
Accuracy: ± 2%FS
Repeatability: ±1%FS
Zero drift: ±1%FS/7d
Range Drift: ±1%FS/7d
Linear error limit: ±1%FS
Response time: T90<=60 s (sample flow 0.5 L/min)
Analog signal :4~20 mA/0~20mA/0~1 V/0-5V/0-10V/1-5V, can set analog output mode freely
Maximum load: provided according to user requirements, not affected by load within 500Ω maximum load
Ambient temperature :-10~45°C, ambient humidity: less than 80% RH
Supply voltage :85-264 VAC 50/60HZ
Size :19-inch profile chassis Lx Wx H=483 mm x300mmx 177mm
Gas flow measured: 500~1000 ml/min,500 ml/min best
Dust: particles not exceeding I um, not exceeding 200 μg/Nm3
Pressure :10%± atmospheric pressure (air outlet should be atmospheric pressure)
Moisture: no more than 5 P saturated (no condensation)
Widely used in petroleum, chemical, smelting, building materials, light industry and other furnace, kiln or flue gas analysis, environmental monitoring, bioengineering, medical and health research and other reliable testing tools.
Notice of Order (Please specify when ordering):
A,φ6 hose connection (standard)
B,1/4"-φ6 stainless steel jacket
C,1/8"-φ3 stainless steel jacket
2. filters: GF2800,AF2000;
3. the measured gas components and measuring range;
4. gas pressure under test: positive, micro or negative pressure;
5. the main components, impurities, sulfides of the gas under test.