Gnl-2100L Portable High Content Oxygen Analyzer

Product Details
Customization: Available
After-sales Service: Overseas Service Available
Warranty: 36months
Still deciding? Get samples of US$ 650/Piece
Request Sample
Diamond Member Since 2020

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 6 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
Medical Device Quality Management System Certification
to see all verified strength labels (17)
  • Gnl-2100L Portable High Content Oxygen Analyzer
  • Gnl-2100L Portable High Content Oxygen Analyzer
  • Gnl-2100L Portable High Content Oxygen Analyzer
  • Gnl-2100L Portable High Content Oxygen Analyzer
  • Gnl-2100L Portable High Content Oxygen Analyzer
  • Gnl-2100L Portable High Content Oxygen Analyzer
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • FAQ
Overview

Basic Info.

Place of Origin
Shanghai China (Mainland)
Accuracy
≤±5% F.S(10~100ppm); ≤±2%
Measure Range
10~99.99% O2
Sensor Life
20000 Hours
Transport Package
as Per Customer Request
Specification
SGS
Trademark
ChangAi
Origin
Beijing, China.
HS Code
9027100090
Production Capacity
200 Units Per Month

Product Description

Product Description

GNL-2100L Portable High Content Oxygen Analyzer
 
Gnl-2100L Portable High Content Oxygen AnalyzerGnl-2100L Portable High Content Oxygen Analyzer

Instruction :
GNL-2100L purity oxygen analyzer is with ion current principle, which is capable of oxygen purity measurement range 10-99.99%.
GNL - 2100L use 3D ion current sensor for measuring unit, through the sensor signal amplifying, filtering, linearization correction after electric processing, through the microprocessor calculated nitrogen oxygen mixed gas concentration of o2, and provides the oxygen concentration. Analyzer with high precision, good stability, long life and other characteristics, suitable for a variety of environments, nitrogen and oxygen mixed gas of oxygen concentration measurement.
Features                                                                                                   
  1. with microprocessor as the core, 3D ion current sensor for measuring unit, with intelligent, good stability, high precision, calibration cycle is long, etc;
  2. Display intuitive, rich: 128 x 64 LCD screen window shows oxygen concentration, menus, data and equipment working status, display intuitive, rich in content;
  3. Technology, using the latest touch buttons, easy to operate, buttons with long life;
  4. Long standby time: built-in high capacity lithium battery, normal use, standby time is not less than 8 hours;
  5. Change analyzer menu lock switch: to prevent wrong operation parameter affect the normal operation;
  6. Alarm function: such as oxygen concentration deviates from the value of the set alarm, the analyzer will send out alarm, alarm value can be set up in full scale range.
Technical Specifications                                                                                      
Model:                           GNL-2100L
Measure Range:                   10-99.99% O2
Principle:                          3D Ion flow oxygen sensor
Measure Mode:                    Portable
Install:                            Dial mounted
Application:                       Non dangerous general applications
Measure Accuracy:                 ≤±1% F.S.
Repeatability:                      ≤±0.5% F.S.
Stability:                          ≤±0.5% F.S./7d
Response Time:                    T90<20s (after full preheating)
Display Resolution:                 0.01%
Standby time:                     more than 8hours
Sensor life:                       more than 2years (normal use)
Instrument life:                    more than 5years (normal use)
Power Supply:                     AC85~264V, 50/HZ
Analyzer power consumption:        <25VA
Display:                         128*64 LCD
Keys:                           Four keys (touch keys)
Environment Temperature:           -10~45ºC
Sample Gas Flow:                  400~600ml/min
Sample Gas Pressure:              atmospheric conditionst +/-10%(Gas outlet should be atmospheric conditions)
Alarm output:                  1 set,Relay contact point capacity:24VDC,0.2A
Analog output:       1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/1-5V,(You can set the mode freely).
Communication:       RS485(standard)/RS232(optional)
Application:                                                                                      
  1. It is widely used in air separation industry,such as pressure swing adsorption(PSA)nitrogen production;
  2. Chemical and smelting industries;
  3. Medical and health industry,such as hyperbsaric oxygen chamber,infant incubator,ventilator, anesthesia machine;
  4. Determination of oxygen concentration in family,ship,underground command center, tunnel,deep well,civil air defense engineering,city tunnel,etc.
 
 
 

Company Profile

Gnl-2100L Portable High Content Oxygen AnalyzerGnl-2100L Portable High Content Oxygen AnalyzerGnl-2100L Portable High Content Oxygen Analyzer
 

FAQ


How to order
1. Measure range
2. Tested gas pressure
3. Gas composition and impurity
 
 


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier